  "as_of": "2026-06-20",
  "citations": {
    "c1": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2026-06-20",
        "raw_file_sha256": "532f93c072af76c3df17cbc682b9b0c6e431f0b67be0c68f12ba43735fecc0d5",
        "sheet": "Data",
        "source_file": "pjm-queue_2026-06-20_sample.xlsx",
        "source_id": "energy.pjm.queue",
        "source_row": 5,
        "source_url": "https://www.pjm.com/planning/services-requests/interconnection-queues.aspx"
      }
    },
    "c2": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2026-06-20",
        "raw_file_sha256": "532f93c072af76c3df17cbc682b9b0c6e431f0b67be0c68f12ba43735fecc0d5",
        "sheet": "Data",
        "source_file": "pjm-queue_2026-06-20_sample.xlsx",
        "source_id": "energy.pjm.queue",
        "source_row": 1,
        "source_url": "https://www.pjm.com/planning/services-requests/interconnection-queues.aspx"
      }
    },
    "c3": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2026-06-20",
        "raw_file_sha256": "532f93c072af76c3df17cbc682b9b0c6e431f0b67be0c68f12ba43735fecc0d5",
        "sheet": "Data",
        "source_file": "pjm-queue_2026-06-20_sample.xlsx",
        "source_id": "energy.pjm.queue",
        "source_row": 6,
        "source_url": "https://www.pjm.com/planning/services-requests/interconnection-queues.aspx"
      }
    },
    "c4": {
      "source_rows_count": 2,
      "verify": {
        "as_of": "2026-06-20",
        "raw_file_sha256": "532f93c072af76c3df17cbc682b9b0c6e431f0b67be0c68f12ba43735fecc0d5",
        "sheet": "Data",
        "source_file": "pjm-queue_2026-06-20_sample.xlsx",
        "source_id": "energy.pjm.queue",
        "source_row": 2,
        "source_url": "https://www.pjm.com/planning/services-requests/interconnection-queues.aspx"
      }
    },
    "c5": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2026-06-20",
        "raw_file_sha256": "532f93c072af76c3df17cbc682b9b0c6e431f0b67be0c68f12ba43735fecc0d5",
        "sheet": "Data",
        "source_file": "pjm-queue_2026-06-20_sample.xlsx",
        "source_id": "energy.pjm.queue",
        "source_row": 4,
        "source_url": "https://www.pjm.com/planning/services-requests/interconnection-queues.aspx"
      }
    },
    "c6": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2026-06-20",
        "raw_file_sha256": "532f93c072af76c3df17cbc682b9b0c6e431f0b67be0c68f12ba43735fecc0d5",
        "sheet": "Data",
        "source_file": "pjm-queue_2026-06-20_sample.xlsx",
        "source_id": "energy.pjm.queue",
        "source_row": 8,
        "source_url": "https://www.pjm.com/planning/services-requests/interconnection-queues.aspx"
      }
    },
    "c7": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2026-06-20",
        "raw_file_sha256": "532f93c072af76c3df17cbc682b9b0c6e431f0b67be0c68f12ba43735fecc0d5",
        "sheet": "Data",
        "source_file": "pjm-queue_2026-06-20_sample.xlsx",
        "source_id": "energy.pjm.queue",
        "source_row": 7,
        "source_url": "https://www.pjm.com/planning/services-requests/interconnection-queues.aspx"
      }
    }
  },
  "notes": [
    {
      "code": "requested_not_built",
      "field": "requested_max_output_mw",
      "message": "The requested_* megawatts (requested_max_output_mw / requested_summer_mw / requested_winter_mw) are REQUESTED interconnection capacity (the PJM New Services queue / waiting line), NOT built, installed, or operating capacity. Historically most queued capacity withdraws before it is built, so a requested-MW total is not a measure of capacity that exists or will exist. Filter `status` (e.g. Active / Withdrawn / In Service) to scope the queue. PJM also reports `in_service_mw` \u2014 the realized BUILT MW for in-service projects (a separate, built figure, not a request). For operating capacity use query_power_capacity_v1. PJM only \u2014 never summed or compared across ISOs; for the MISO queue use query_power_interconnection_queue_v1."
    },
    {
      "code": "no_status_filter",
      "field": "status",
      "message": "No status filter was applied, so this total spans ALL statuses \u2014 the PJM queue is dominated by Withdrawn requests; the live pipeline is status=Active (plus Under Construction / In Service for built projects). Pass filters INSIDE a `params` object, e.g. {\"params\": {\"status\": \"Active\"}} \u2014 a filter at the top level is ignored by the MCP transport and returns the full, unscoped queue."
    }
  ],
  "primitive": "query_power_interconnection_queue_pjm_v1",
  "query": {
    "as_of": "2026-06-20",
    "group_by": [
      "state"
    ],
    "include_records": false,
    "order_by": "requested_max_output_mw",
    "top_n": 10
  },
  "rows": [
    {
      "group": {
        "state": "IL"
      },
      "lineage": {
        "citation_ref": "c1"
      },
      "metrics": {
        "in_service_mw": null,
        "requested_max_output_mw": 1610.0,
        "requested_summer_mw": 135.0,
        "requested_winter_mw": 0.0,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "state": "PA"
      },
      "lineage": {
        "citation_ref": "c2"
      },
      "metrics": {
        "in_service_mw": 673.0,
        "requested_max_output_mw": 720.0,
        "requested_summer_mw": 673.0,
        "requested_winter_mw": 720.0,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "state": "VA"
      },
      "lineage": {
        "citation_ref": "c3"
      },
      "metrics": {
        "in_service_mw": 311.8,
        "requested_max_output_mw": 315.0,
        "requested_summer_mw": 315.0,
        "requested_winter_mw": 315.0,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "state": "MD"
      },
      "lineage": {
        "citation_ref": "c4"
      },
      "metrics": {
        "in_service_mw": null,
        "requested_max_output_mw": 200.0,
        "requested_summer_mw": 131.76,
        "requested_winter_mw": 105.0,
        "source_record_count": 2
      }
    },
    {
      "group": {
        "state": "WV"
      },
      "lineage": {
        "citation_ref": "c5"
      },
      "metrics": {
        "in_service_mw": 132.5,
        "requested_max_output_mw": 186.0,
        "requested_summer_mw": 37.2,
        "requested_winter_mw": 186.0,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "state": "NJ"
      },
      "lineage": {
        "citation_ref": "c6"
      },
      "metrics": {
        "in_service_mw": 157.5,
        "requested_max_output_mw": 180.0,
        "requested_summer_mw": null,
        "requested_winter_mw": 180.0,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "state": "DC"
      },
      "lineage": {
        "citation_ref": "c7"
      },
      "metrics": {
        "in_service_mw": null,
        "requested_max_output_mw": 0.0,
        "requested_summer_mw": null,
        "requested_winter_mw": null,
        "source_record_count": 1
      }
    }
  ],
  "source_id": "energy.pjm.queue",
  "summary": {
    "group_count": 7,
    "totals": {
      "in_service_mw": 1274.8,
      "requested_max_output_mw": 3211.0,
      "requested_summer_mw": 1291.96,
      "requested_winter_mw": 1506.0,
      "source_record_count": 8
    }
  }
}