  "as_of": "2025-02-28",
  "citations": {
    "c1": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2025-02-28",
        "raw_file_sha256": "fea77403b0d2a824df60ee6809ee1250e4e88cfb04ae7b1307f74e36e55f2cca",
        "sheet": "page:1",
        "source_file": "pjm_elcc_2026-27_bra_sample.pdf",
        "source_id": "energy.pjm.elcc",
        "source_row": 22,
        "source_url": "https://www.pjm.com/planning/resource-adequacy-planning/effective-load-carrying-capability"
      }
    },
    "c2": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2025-02-28",
        "raw_file_sha256": "fea77403b0d2a824df60ee6809ee1250e4e88cfb04ae7b1307f74e36e55f2cca",
        "sheet": "page:1",
        "source_file": "pjm_elcc_2026-27_bra_sample.pdf",
        "source_id": "energy.pjm.elcc",
        "source_row": 19,
        "source_url": "https://www.pjm.com/planning/resource-adequacy-planning/effective-load-carrying-capability"
      }
    },
    "c3": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2025-02-28",
        "raw_file_sha256": "fea77403b0d2a824df60ee6809ee1250e4e88cfb04ae7b1307f74e36e55f2cca",
        "sheet": "page:1",
        "source_file": "pjm_elcc_2026-27_bra_sample.pdf",
        "source_id": "energy.pjm.elcc",
        "source_row": 20,
        "source_url": "https://www.pjm.com/planning/resource-adequacy-planning/effective-load-carrying-capability"
      }
    },
    "c4": {
      "source_rows_count": 1,
      "verify": {
        "as_of": "2025-02-28",
        "raw_file_sha256": "fea77403b0d2a824df60ee6809ee1250e4e88cfb04ae7b1307f74e36e55f2cca",
        "sheet": "page:1",
        "source_file": "pjm_elcc_2026-27_bra_sample.pdf",
        "source_id": "energy.pjm.elcc",
        "source_row": 21,
        "source_url": "https://www.pjm.com/planning/resource-adequacy-planning/effective-load-carrying-capability"
      }
    }
  },
  "notes": [
    {
      "code": "marginal_elcc_not_capacity_factor",
      "field": "elcc_rating",
      "message": "Ratings are marginal ELCC values specific to an auction document's assumed resource mix. They are accreditation fractions for PJM capacity-market purposes, NOT physical capacity factors, and they change auction to auction. Document identities are never merged or reconciled."
    },
    {
      "code": "preliminary_vs_final",
      "field": "document_kind",
      "message": "Preliminary-outlook ratings are forward guidance and routinely differ from the final auction's ratings for the same delivery year; consumers wanting the binding value for a delivery year should filter document_kind=final_auction."
    }
  ],
  "primitive": "query_power_capacity_accreditation_pjm_v1",
  "query": {
    "as_of": "2025-02-28",
    "class_family": [
      "storage_4h",
      "storage_6h",
      "storage_8h",
      "storage_10h"
    ],
    "delivery_year": [
      "2026/2027"
    ],
    "document_kind": [
      "final_auction"
    ],
    "group_by": [
      "document_kind",
      "auction_label",
      "delivery_year",
      "resource_class",
      "class_family"
    ],
    "include_records": false
  },
  "rows": [
    {
      "group": {
        "auction_label": "2026/2027 BRA",
        "class_family": "storage_10h",
        "delivery_year": "2026/2027",
        "document_kind": "final_auction",
        "resource_class": "10-hr Storage"
      },
      "lineage": {
        "citation_ref": "c1"
      },
      "metrics": {
        "avg_elcc_rating": 0.72,
        "max_elcc_rating": 0.72,
        "min_elcc_rating": 0.72,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "auction_label": "2026/2027 BRA",
        "class_family": "storage_4h",
        "delivery_year": "2026/2027",
        "document_kind": "final_auction",
        "resource_class": "4-hr Storage"
      },
      "lineage": {
        "citation_ref": "c2"
      },
      "metrics": {
        "avg_elcc_rating": 0.5,
        "max_elcc_rating": 0.5,
        "min_elcc_rating": 0.5,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "auction_label": "2026/2027 BRA",
        "class_family": "storage_6h",
        "delivery_year": "2026/2027",
        "document_kind": "final_auction",
        "resource_class": "6-hr Storage"
      },
      "lineage": {
        "citation_ref": "c3"
      },
      "metrics": {
        "avg_elcc_rating": 0.58,
        "max_elcc_rating": 0.58,
        "min_elcc_rating": 0.58,
        "source_record_count": 1
      }
    },
    {
      "group": {
        "auction_label": "2026/2027 BRA",
        "class_family": "storage_8h",
        "delivery_year": "2026/2027",
        "document_kind": "final_auction",
        "resource_class": "8-hr Storage"
      },
      "lineage": {
        "citation_ref": "c4"
      },
      "metrics": {
        "avg_elcc_rating": 0.62,
        "max_elcc_rating": 0.62,
        "min_elcc_rating": 0.62,
        "source_record_count": 1
      }
    }
  ],
  "source_id": "energy.pjm.elcc",
  "summary": {
    "group_count": 4,
    "totals": {
      "avg_elcc_rating": 0.605,
      "max_elcc_rating": 0.72,
      "min_elcc_rating": 0.5,
      "source_record_count": 4
    }
  }
}